<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Cheap Cladding &#187; wood panellingCheap Cladding</title>
	<atom:link href="http://cheapcladding.com.au/tag/wood-panelling/feed/" rel="self" type="application/rss+xml" />
	<link>http://cheapcladding.com.au</link>
	<description></description>
	<lastBuildDate>Tue, 16 Apr 2013 18:07:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.1</generator>
		<item>
		<title>6 Fire Rated Construction Details QT Eco Series</title>
		<link>http://cheapcladding.com.au/6-fire-rated-construction-details-qt-eco-series/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=6-fire-rated-construction-details-qt-eco-series</link>
		<comments>http://cheapcladding.com.au/6-fire-rated-construction-details-qt-eco-series/#comments</comments>
		<pubDate>Mon, 15 Apr 2013 08:52:09 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[QT Eco Series]]></category>
		<category><![CDATA[3d wall panels]]></category>
		<category><![CDATA[aluminium cladding for houses]]></category>
		<category><![CDATA[cedar cladding]]></category>
		<category><![CDATA[exterior cladding panels]]></category>
		<category><![CDATA[external cladding]]></category>
		<category><![CDATA[external wall cladding products]]></category>
		<category><![CDATA[house cladding brisbane]]></category>
		<category><![CDATA[outdoor cladding]]></category>
		<category><![CDATA[outdoor wall cladding]]></category>
		<category><![CDATA[outdoor wall panels]]></category>
		<category><![CDATA[outside wall cladding]]></category>
		<category><![CDATA[rock cladding]]></category>
		<category><![CDATA[timber cladding for houses]]></category>
		<category><![CDATA[weatherboard homes]]></category>
		<category><![CDATA[wood panelling]]></category>

		<guid isPermaLink="false">http://cheapcladding.com.au/?p=1014</guid>
		<description><![CDATA[Note: Prior to any firewalls being constructed it is essential that the builder consults with the project certifier to ensure that the certifier is aware of the firewall construction procedures and the certifier deems the installer competent. Fire Resistance Level (FRL) is assessed by three performance measures:- Structural Adequacy / Integrity /Insulation eg 90/90/90 6.1 FRL &#8211; 90 Mins. [...]]]></description>
				<content:encoded><![CDATA[<p><strong><span style="color: #cc99ff;">Note: Prior to any firewalls being constructed it is essential that the builder consults with the project certifier to ensure that the certifier is aware of the firewall construction procedures and the certifier deems the installer competent.</span></strong></p>
<p>Fire Resistance Level (<strong>FRL</strong>) is assessed by three performance measures:- <strong>Structural Adequacy / Integrity /Insulation</strong> eg 90/90/90</p>
<h3><span style="color: #800080;"><strong>6.1 FRL &#8211; 90 Mins. &amp; External Fire Source</strong></span></h3>
<p><strong>CSIRO</strong> Full-Scale Fire Test <span style="color: #99cc00;">FS 3685/2695</span> has proven that the QT EcoSeries Wall System (shown right) is capable of achieving a fire resistance of <strong>113 minutes</strong> Integrity and <strong>115 minutes</strong> Insulation when tested in accordance with <span style="color: #ff6600;">AS1530.4</span>. Therefore for the purpose of Building Regulations in Australia, the QT EcoSeries Wall System achieved a fire resistance level (<strong>FRL</strong>) of <strong>90/90/90</strong>. The <strong>FRL</strong> is applicable for exposure to fire source from the tested side (QT EcoSeries Wall Panel side).</p>
<p style="text-align: center;"><a href="http://thewallstore.com.au/QT_Eco_Series.html"><img class="size-full wp-image-1017 aligncenter" alt="Fire Test" src="http://cheapcladding.com.au/wp-content/uploads/2013/04/Fire-Test.png" width="328" height="407" /></a></p>
<p style="text-align: center;"><a href="http://thewallstore.com.au/QT_Eco_Series.html"><img class="size-full wp-image-1018 aligncenter" alt="fire rated vertical control joints and fire rated horizontal control joints" src="http://cheapcladding.com.au/wp-content/uploads/2013/04/fire-rated-vertical-control-joints-and-fire-rated-horizontal-control-joints.png" width="698" height="390" /></a></p>
<p>The Fire Rating information for sections 6.2, 6.3, and 6.4 are based on CSIRO Opinion FCO-2310 Dated 17th February 2004.</p>
<h3><span style="color: #800080;"><strong>6.2 FRL &#8211; 90 Minutes</strong></span></h3>
<p>To achieve a <strong>90 minute</strong> Fire Rating the wall must be constructed so as the wall consists of two layers of <strong>13mm</strong> thick fire resistance plasterboard affixed to the timber frame internally and one layer of fire resistant building foil, one layer of <strong>50mm</strong> QT EcoSeries Wall Panel with a <strong>5-8mm</strong> render applied with finish, affixed directly to a <strong>20-50mm</strong> battened out cavity. This system would be capable of achieving Fire Resistance Levels of <strong>-/90/90</strong> for Non Load Bearing walls and <strong>90/90/90</strong> for Load Bearing Walls designed in accordance with <span style="color: #ff6600;">AS1684</span> for fire exposure from either direction if tested in accordance with <span style="color: #ff6600;">AS1530.4</span></p>
<p style="text-align: center;"><a href="http://thewallstore.com.au/QT_Eco_Series.html"><img class="size-full wp-image-1019 aligncenter" alt="90 Minute Fire Rated Wall" src="http://cheapcladding.com.au/wp-content/uploads/2013/04/90-Minute-Fire-Rated-Wall.png" width="324" height="446" /></a></p>
<h3><span style="color: #800080;"><strong>6.3 Extended Wall Areas</strong></span></h3>
<p>The Fire Resistance Levels of <strong>60</strong> &amp; <strong>90 minutes</strong> would still apply to the same system extended in height in modular form provided that the structural members are designed in accordance with the relevant structural design code for the height and load of actual installation and an approved joint system appropriate to the <strong>FRL</strong> and the width of the gap is used for the horizontal and vertical joints in a manner as detailed in the attached drawings.</p>
<p style="text-align: center;"><a href="http://thewallstore.com.au/QT_Eco_Series.html"><img class="aligncenter size-full wp-image-1066" alt="QTEcoSeries Exterior Wall System" src="http://cheapcladding.com.au/wp-content/uploads/2013/04/QTEcoSeries-Exterior-Wall-System.png" width="684" height="456" /></a> <a href="http://thewallstore.com.au/QT_Eco_Series.html" target="_self"><img class="alignright" alt="find out more" src="http://thewallstore.com.au/images/findoutmore_off.png" width="131" height="29" name="findout" border="0" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://cheapcladding.com.au/6-fire-rated-construction-details-qt-eco-series/feed/</wfw:commentRss>