2 Installation and Fixing QT Eco Series

by

2.1 Panel fixings

Fix the QT EcoSeries Wall Panel onto timber battens or metal channels with galvanised
75mm x 3.15 or 3.75mm ring shank nails (timber battens only) or 10g x 75mm Class 3 (AS3566) screws (timber or steel battens) with the addition of QT Buttons in all cases. Panel fixings must be no closer than 50mm but no further than 112mm to the horizontal panel edge and no closer than 50mm to the vertical edge, while normal fixing centres are at 225mm maximum centres. It is essential that the vertical and horizontal butt joints be bonded with polyurethane foam adhesive. Also ensure polyurethane foam adhesive is applied to all batten faces prior to the panel being pushed against them for maximum bonding to the support frame. Panels can be joined off stud, if glued to the abutting panel with polyurethane foam adhesive. QT EcoSeries Wall Panels can span 225mm as an unsupported cantilever. Panels must span across a minimum of two channels or battens and must be installed in a horizontal stretcher bond pattern. To prevent corrosion from salt aerosols in high corrosion zones, (such as geothermal activity or within a 500m distance from the sea) upgrade fixing screws to class 4 or stainless steel (AS3566).

50mm panel fixing 50mm panel edge detail

2. 2 Framing

Timber framing must comply with AS 1684 and steel framing must be designed and constructed in accordance with AS 3623. Minimum distances from end and edge of timber framing members must be observed to avoid splitting. Stud spacing must not exceed 600mm centres. Noggings must be fitted between studs at 1350mm maximum centres.

With a 1.8 m spirit level, check for variations in the frame that are over 6 mm. Large variations negatively affect weather protection or can appear as visual defects under critical light conditions. If the frame is out of plumb, but not structurally defective, consult with the builder or contractor for remediation.

clip and channel system timber batten system

find out more

Duraplank BGC FIBRE CEMENT

by

duraplank external claddingBGC Duraplank is designed and manufactured as a plank which is reminiscent of traditional weatherboards both in appearance and installation methods. BGC Duraplank is not subject to decay, rot or white ant damage and is non combustible. The result is a safer, more durable cladding that requires minimum maintenance.

BGC Duraplank is available with a smooth finish, woodgrain (Douglas Fir) or rusticated texture for that authentic weatherboard look. Duraplank has the strength to withstand the rigours of normal family activities.

Duraplank:

  • reminiscent of traditional weatherboards
  • not subject to decay, rot or white ant damage
  • safe and durable
  • available in 3 different profiles
THICKNESS
(mm)
WIDTH
(mm & PATTERN)
LENGTH
(mm)
7.5 300 Smooth & Woodgrain 4200
230 Smooth & Woodgrain 4200
205 Rusticated 4200

*some sizes may not be available in all states, please check with your local BGC office for availability.

duraplank smooth woodgrain rustified