<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Cheap Cladding &#187; timber claddingCheap Cladding</title>
	<atom:link href="http://cheapcladding.com.au/tag/timber-cladding/feed/" rel="self" type="application/rss+xml" />
	<link>http://cheapcladding.com.au</link>
	<description></description>
	<lastBuildDate>Tue, 16 Apr 2013 18:07:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.1</generator>
		<item>
		<title>2 Installation and Fixing QT Eco Series</title>
		<link>http://cheapcladding.com.au/2-installation-and-fixingqt-eco-series/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=2-installation-and-fixingqt-eco-series</link>
		<comments>http://cheapcladding.com.au/2-installation-and-fixingqt-eco-series/#comments</comments>
		<pubDate>Tue, 16 Apr 2013 05:07:57 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[QT Eco Series]]></category>
		<category><![CDATA[aluminium wall cladding]]></category>
		<category><![CDATA[cladding australia]]></category>
		<category><![CDATA[exterior cladding materials]]></category>
		<category><![CDATA[exterior wall cladding]]></category>
		<category><![CDATA[external cladding for houses]]></category>
		<category><![CDATA[external cladding products]]></category>
		<category><![CDATA[foam cladding]]></category>
		<category><![CDATA[house cladding]]></category>
		<category><![CDATA[house cladding materials]]></category>
		<category><![CDATA[pvc wall panels]]></category>
		<category><![CDATA[stone cladding]]></category>
		<category><![CDATA[timber cladding]]></category>
		<category><![CDATA[vinyl weatherboard cladding]]></category>
		<category><![CDATA[weatherboard cladding]]></category>

		<guid isPermaLink="false">http://cheapcladding.com.au/?p=1084</guid>
		<description><![CDATA[2.1 Panel fixings Fix the QT EcoSeries Wall Panel onto timber battens or metal channels with galvanised 75mm x 3.15 or 3.75mm ring shank nails (timber battens only) or 10g x 75mm Class 3 (AS3566) screws (timber or steel battens) with the addition of QT Buttons in all cases. Panel fixings must be no closer than 50mm [...]]]></description>
				<content:encoded><![CDATA[<h3><strong><span style="color: #800080;">2.1 Panel fixings</span></strong></h3>
<p>Fix the QT EcoSeries Wall Panel onto timber battens or metal channels with galvanised<br />
<strong>75mm x 3.15 or 3.75mm</strong> ring shank nails (timber battens only) or <strong>10g x 75mm Class 3</strong> (<span style="color: #ff6600;">AS3566</span>) screws (timber or steel battens) with the addition of QT Buttons in all cases. Panel fixings must be no closer than <strong>50mm</strong> but no further than <strong>112mm</strong> to the horizontal panel edge and no closer than <strong>50mm</strong> to the vertical edge, while normal fixing centres are at <strong>225mm</strong> maximum centres. It is essential that the vertical and horizontal butt joints be bonded with polyurethane foam adhesive. Also ensure polyurethane foam adhesive is applied to all batten faces prior to the panel being pushed against them for maximum bonding to the support frame. Panels can be joined off stud, if glued to the abutting panel with polyurethane foam adhesive. QT EcoSeries Wall Panels can span <strong>225mm</strong> as an unsupported cantilever. Panels must span across a minimum of two channels or battens and must be installed in a horizontal stretcher bond pattern. To prevent corrosion from salt aerosols in high corrosion zones, (such as geothermal activity or within a <strong>500m</strong> distance from the sea) upgrade fixing screws to <strong>class 4</strong> or stainless steel (<span style="color: #ff6600;">AS3566</span>).</p>
<p style="text-align: center;"><a href="http://thewallstore.com.au/QT_Eco_Series.html"><img class="aligncenter size-full wp-image-1085" alt="50mm panel fixing 50mm panel edge detail" src="http://cheapcladding.com.au/wp-content/uploads/2013/04/50mm-panel-fixing-50mm-panel-edge-detail.png" width="691" height="335" /></a></p>
<h3><strong><span style="color: #800080;">2. 2 Framing</span></strong></h3>
<p>Timber framing must comply with <span style="color: #ff6600;">AS 1684</span> and steel framing must be designed and constructed in accordance with <span style="color: #ff6600;">AS 3623</span>. Minimum distances from end and edge of timber framing members must be observed to avoid splitting. Stud spacing must not exceed <strong>600mm</strong> centres. Noggings must be fitted between studs at <strong>1350mm</strong> maximum centres.</p>
<p>With a <strong>1.8 m</strong> spirit level, check for variations in the frame that are over <strong>6 mm</strong>. Large variations negatively affect weather protection or can appear as visual defects under critical light conditions. If the frame is out of plumb, but not structurally defective, consult with the builder or contractor for remediation.</p>
<p style="text-align: center;"><a href="http://thewallstore.com.au/QT_Eco_Series.html"><img class="aligncenter size-full wp-image-1086" alt="clip and channel system timber batten system" src="http://cheapcladding.com.au/wp-content/uploads/2013/04/clip-and-channel-system-timber-batten-system.png" width="727" height="865" /></a></p>
<p><a href="http://thewallstore.com.au/QT_Eco_Series.html" target="_self"><img class="alignright" alt="find out more" src="http://thewallstore.com.au/images/findoutmore_off.png" width="131" height="29" name="findout" border="0" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://cheapcladding.com.au/2-installation-and-fixingqt-eco-series/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>5.0 Architectural Specification PowerFloor</title>
		<link>http://cheapcladding.com.au/5-0-architectural-specification-powerfloor/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=5-0-architectural-specification-powerfloor</link>
		<comments>http://cheapcladding.com.au/5-0-architectural-specification-powerfloor/#comments</comments>
		<pubDate>Fri, 05 Apr 2013 03:51:09 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[CSR Hebel Power Floor Design Guide]]></category>
		<category><![CDATA[aac hebel]]></category>
		<category><![CDATA[autoclaved aerated concrete]]></category>
		<category><![CDATA[colorbond wall cladding]]></category>
		<category><![CDATA[csr hebel powerpanel]]></category>
		<category><![CDATA[external wall cladding]]></category>
		<category><![CDATA[hebel concrete]]></category>
		<category><![CDATA[hebel power wall]]></category>
		<category><![CDATA[hebel powerpanel]]></category>
		<category><![CDATA[house cladding options]]></category>
		<category><![CDATA[insulated concrete forms]]></category>
		<category><![CDATA[internal wall systems]]></category>
		<category><![CDATA[lightweight concrete]]></category>
		<category><![CDATA[metal cladding]]></category>
		<category><![CDATA[steel flooring systems]]></category>
		<category><![CDATA[timber cladding]]></category>
		<category><![CDATA[wall cladding systems]]></category>

		<guid isPermaLink="false">http://cheapcladding.com.au/?p=541</guid>
		<description><![CDATA[This specification should be adopted as a guide only, and shall be superseded by the contract specifications of the project. * Insert or select appropriate specifications. Scope The contractor shall furnish all material and equipment required to satisfactorily complete the installation and jointing of Hebel PowerFloor where indicated in the contract specification. Materials All AAC [...]]]></description>
				<content:encoded><![CDATA[<p>This specification should be adopted as a guide only, and shall be superseded by the contract specifications of the project.</p>
<h6><span style="color: #ffcc00;">* Insert or select appropriate specifications.</span></h6>
<h3><strong><span style="color: #0000ff;">Scope</span></strong></h3>
<p>The contractor shall furnish all material and equipment required to satisfactorily complete the installation and jointing of Hebel PowerFloor where indicated in the contract specification.</p>
<h3><strong><span style="color: #0000ff;">Materials</span></strong></h3>
<p>All AAC material shall be a Hebel PowerFloor panel as manufactured by CSR Hebel.</p>
<p>All accompanying fixings shall be those supplied by CSR Hebel or approved by the project engineer.</p>
<p>All lining materials shall be Gyprock plasterboard as manufactured and supplied by CSR Gyprock (or products of equivalent or better performance). All plasterboard shall be manufactured to meet the dimensional requirements of <span style="color: #ff00ff;">AS/NZS2588</span> ‘<span style="color: #00ccff;">Gypsum Plasterboard</span>’.</p>
<p>Steel frame components shall be those manufactured by Rondo Building Services Pty Ltd (or products of equivalent or better performance).</p>
<p>Construction adhesive shall be Fuller Max Bond as manufactured and supplied by Fuller (or products of equivalent or better performance).</p>
<p>All sealants shall be a polyurethane type with required fire and acoustic ratings, (or products of equivalent or better performance).</p>
<p>All infill materials shall be products manufactured and supplied by CSR Bradford (or products of equivalent or better performance).</p>
<h3><strong><span style="color: #0000ff;">Power Floor System</span></strong></h3>
<p>The contractor shall supply and install a Hebel PowerFloor system <em><span style="color: #ff00ff;">*PF-………(…)</span></em>, in accordance with CSR Hebel Detached Houses &amp; Low Rise Multi-Residential Floor Design Guide, <span style="color: #00ffff;">NºHBLA185</span>, and CSR Gyprock Fibre Cement Fire &amp; Acoustic Design Guide (&#8216;<span style="color: #ff0000;">The Red Book</span>&#8216;), <span style="color: #00ffff;">NºGYP500</span>, and shall satisfy the following performance criteria.</p>
<p>The Hebel PowerFloor system shall have a Fire Resistance Level of <em><span style="color: #00ff00;">*<span style="color: #cc99ff;">FRL…/…/…</span></span></em> for a fire source ‘<span style="color: #99cc00;">from above</span>’ in accordance with the requirements of <span style="color: #ff00ff;">AS1530.4</span>. Design of the joists shall allow for temperature effects.</p>
<p>Installation shall be carried out to the level specified for a field acoustic performance of <em><span style="color: #00ff00;">*D<sub>ntw</sub>…………</span></em> using cavity infill of <em><span style="color: #ffcc00;">*Bradford ……………</span></em> (or products of equivalent or better performance).</p>
<h3><strong><span style="color: #0000ff;">Levels of Finish &#8211; Floor Covering</span></strong></h3>
<p>Prior to installation of the floor covering,the contractor shall ensure the installed panels are within the tolerances of the project specifications. The contractor shall ensure that all control joints are installed as per project specifications, panel joints are completely filled with Hebel Adhesive, minor chipping damage of the panels shall be patched with Hebel Mortar, and all sealants are installed as per manufacturer’s specifications.</p>
<p>Floor coverings shall be installed as per manufacturer’s specifications, unless specified otherwise in the contract documentation.</p>
<h3><strong><span style="color: #0000ff;">Ceiling System</span></strong></h3>
<p>The contractor shall supply and install the Gyprock Ceiling System <em><span style="color: #99cc00;">*N°CSR………</span></em> in accordance with CSR Gyprock Fibre Cement Fire &amp; Acoustic Design Guide (&#8216;<span style="color: #ff0000;">The Red Book</span>&#8216;), NºGYP500. The ceiling framing shall be lined with <em><span style="color: #ff99cc;">*……… layers of……… mm Gyprock……… plasterboard</span></em>.</p>
<h3><strong><span style="color: #0000ff;">Levels of Finish-Ceiling Systems</span></strong></h3>
<p>All ceiling framing systems, plasterboard lining, jointing and finishing shall be carried out to <em><span style="color: #ff6600;">*Level ………</span></em> Level of Finish, in accordance with CSR Gyprock Plasterboard Residential Installation Guide, <span style="color: #00ffff;">NºGYP547</span>, <span style="color: #ff00ff;">AS/NZS2589.1</span> ‘Gypsum Linings in Residential and Light Commercial Construction &#8211; Application and Finishing’.</p>
<h3><strong><span style="color: #0000ff;">Plasterboard</span></strong></h3>
<p>The Hebel PowerFloor system ceiling framing shall be lined with <em><span style="color: #cc99ff;">*………… layer/s of …………mm Gyprock ……………… plasterboard</span></em>.</p>
<p>All layers shall be fixed to the framing (ie., timber or steel floor joists and/or steel furring channels) as specified for the relevant system in the CSR Gyprock Ceiling Systems Installation Guide, <span style="color: #00ffff;">NºGYP570</span>, other relevant CSR Gyprock technical literature, and Rondo Building Services Pty Ltd literature or steel frame manufacturer’s literature.</p>
<h3><strong><span style="color: #0000ff;">Jointing &amp; Finishing</span></strong></h3>
<p>Jointing and finishing of the outer layer of plasterboard shall be in accordance with the CSR Gyprock Plasterboard Residential Installation Guide, <span style="color: #99cc00;">NºGYP547</span>.</p>
<h3><strong><span style="color: #0000ff;">Caulking</span></strong></h3>
<p>Where caulking is indicated in fire rated systems <span style="color: #ff0000;"><em>*……………………</em></span> fire rated polyurethane sealant or fire rated backing rod with <em><span style="color: #ff0000;">*………………</span></em> acoustic rated polyurethane sealant shall be used, and installed in accordance with the manufacturer’s recommendations.</p>
<p>Where caulking is indicated in wet areas, a <span style="color: #00ff00;"><em>*…………………… polyurethane sealant </em></span>must be used when caulking<span style="color: #ffcc00;"><em> *non-fire rated/fire rated wet areas</em></span>, as indicated, and installed in accordance with the manufacturer’s recommendations.</p>
<h4><span style="color: #0000ff;"><strong>Important</strong></span></h4>
<p>Any variation or substitution of materials or assembly requirements, or compromise in assembly may result in failure under critical conditions.<br />
<a href="http://thewallstore.com.au/Hebel_Boards_Panels.html" target="_self"><img class="alignright" alt="find out more" src="http://thewallstore.com.au/images/findoutmore_off.png" width="131" height="29" name="findout" border="0" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://cheapcladding.com.au/5-0-architectural-specification-powerfloor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
